3.0 INSTALLATION INSTRUCTIONS
MORNINGSTAR CORPORATION 15
Step 3: Mark Holes
Use a pencil or pen to mark the four (4) mounting hole
locations on the mounting surface.
Step 4: Drill Holes
Remove the controller and drill 3/32” (2.5 mm) holes in the
marked locations.
Step 5: Secure Controller
Place the controller on the surface and align the mounting
holes with the drilled holes in step 4. Secure the controller in
place using the mounting screws (included).
3.0
3.4 Wiring
NOTE: A recommended connection order has been
provided for maximum safety during installation.
The controller will not be damaged regardless of the
sequence of connnections.
NOTE: The SS-MPPT is a negative ground controller. Any
combination of negative connections can be earth
grounded as required. Grounding is recommended, but
not required for correct operation.
!
CAUTION: The total current draw of all system loads
connected to the SS-MPPT LOAD terminals cannot
exceed the 15A load current rating.
!
CAUTION: For mobile applications, be sure to secure all
wiring. Use cable clamps to prevent cables from swaying
when the vehicle is in motion. Unsecured cables create
loose and resistive connections which may lead to
excessive heating and/or re.