Specifications
• That an extractor fan is not fitted in the
same room as the fire.
12
5. Fire Blazing Out Of Control
Check that:
• The door or doors are correctly closed.
• The door seals are in good condition.
• The main body gaskets are in good condition. With the
stove running trace along the joints
of the stove with a burning incense stick; if the smoke trail is drawn into the stove at any
point it would indicate a defective seal.
Important note: All Morsø stoves use the same ceramic rope gasket for doors and main body castings.
The use of unauthorised non Morsø gaskets during routine maintenance commonly results in:
• Pressure on the casting and fixing point which can
lead to cracking.
• Inability to fit components due to insufficient
compression of the gasket.
• Inability to close the door or excessive force
required to close the door resulting in dam -
age to both the door casting and the glass.
The following kits are available from your authorised Morsø dealer:
• Sealing rope 2mtr x Ø8mm (doors & body parts)
62903100
• Sealing kit for doors and bogy parts with
adhesive 62904300
• Self adhesive ladder gasket for glass 2mtr x 8mm
62903800
• Glass kit 1410 inc gasket, clips & screws
62904000
• Glass kit 1440 inc gasket, clips & screws
62904100
• Glass kit 1430 inc gasket, clips & screws
62904200
13
14 15