Specifications

USE AS A GENERATING SET
GE 3200 SX
GE 4500 HBS / GE 4500 HBS-AVR
GE 4500 SX / SXE-EAS / SXE-AVR EAS
M
37.1
REV.0-12/11
15/12/11 35470-GB
GENERATION IN C.C. (Continuous Current)
Maximum power in c.c.:
P = 120W - V= 12V AC
I = 10A
Generation in c.c. is mainly used to recharge lead
batteries.
- Verify that the battery to be charged is not a dry
battery, and that it is 12V c.c.
- Position the generator and battery on a at surface
and distant from one another.
- Connect the battery recharge cables one at a time,
avoiding accidental contacts between them.
+ Note: use cables with a minimum section of
6 mm
2
.
- Start the motor.
- Once recharging is complete, proceed in opposite
sequence, switching off the motor and disconnec-
ting the cables, etc.
THERMOPROTECTION
The 12V c.c. output is protected against overloads
by the thermoprotection device (59).
When current is exceeded, the protection feature in-
tervenes to cut off tension to the c.c. terminals (Q4).
+ Notes: the intervention of the thermoprotection
feature is not instantaneous, but reacts according
to an overcurrent/time characteristic, whereby the
greater the overcurrent the quicker the intervention.
In case of intervention by the protection feature,
verify that:
- the c.c. terminal /battery connections respect the
polarities;
- the battery is not faulty or has a short-circuited
element;
- the battery level is not too low, with the consequent
recharge current being too high.
Eliminate the cause and wait a few minutes to allow
the thermoprotection to cool down.
Reset the protection feature by pressing the central
pole. If the protection should intervene once more,
replace it with another one
with matching intervention
current specications and/
or contact the Service De-
partment.
ATTENTION
The batteries produce explosive gas; sparks,
ames, cigarettes, are to be kept far from them.
Make sure that when they are being recharged
there is adequate ventilation around the battery.
The battery contains sulphuric acid (electrolyte).
The contact with eyes and skin may cause se-
vere lesions. Wear protective garments and eye
protections.
If the electrolyte comes in contact with the skin,
wash with plenty of water.
If the electrolyte comes in contact with the
skin,wash with plenty of water.If it comes in contact
with the eyes wash with uent water for at least
15 minutes and rush for a doctor.
The electrolyte is poisonous.
If swallowed drink plenty of water or milk, then milk
of magnesia or vegetable oil and call for a doctor.
Keep away from children.
!
PUSH TO