MAINTENANCE AND CARE TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
®
MAINTENANCE AND CARE
• Wipe clean cords and clamps after each
use.
• Store the power and output cables neatly to
prevent damage.
• The charger housing may be cleaned using
a damp cloth and mild cleaning agent.
• Always unplug the charger when not in use.
• Keep the charger stored in a cool, dry place.
No LEDs illuminate
when plugged into
AC outlet.
Amber (solid) fault
LED is illuminated.
Red (solid) fault
LED is illuminated.
Red (flashing) fault
LED is illuminated.
Clamps are inversely connected
to battery.
Reverse clamp connections.
Battery voltage is still less than
10 V after some time charging.
The battery is defective. Test or replace the battery.
Loose connection at AC power.
Poor clamp connection to battery
posts.
Ensure power is present at AC outlet by plugging in a
different appliance.
Check connection.
Check clamp connection. Ensure battery posts are
clean, and rock clamps back and forth to ensure a
good connection.
Battery voltage is too low (<1.5 V)
to activate the charger.
Check battery voltage with a volt meter. If less than
1.5 V, test or replace battery. (A battery discharged
below 1.5 V is likely beyond salvage due to sulphation
or some other internal failure.)
No AC power at outlet.
TROUBLESHOOTING
Condition
Cause
Solution
Battery has not reached
full charge after 24 hours
of charging.
Remove any loads on the battery while charging and
try charging again.
The battery is defective. Test or replace the battery.
Charger current may be too low for the size (capacity)
of the battery. Try charging the battery with a higher
current charger.
Overheat shutdown.
Battery voltage is too high.
Ensure ventilation to charger is not obstructed.
Move charger to a cooler location. Charging
will resume once charger cools down.
Ensure the battery is 12 V, not 24 V.
Remove any loads on battery while charging and try
charging again.
Input Voltage AC
Working Voltage AC
Input Amps
Charging Voltage
Charging Current
Minimum Battery Voltage
Ambient Operating Temperature
Charger Type
Compatible Battery Voltage
Compatible Battery Types
Compatible Battery Capacity
Cooling
Housing Protection
120 V AC, 60 Hz
104–127 V AC, 60 Hz
0.6 A (max)
12 V NORM: 14.4 V
12 V COLD/AGM: 14.8 V
12 V RECONDITIONING: 15.8 V
6 V NORM: 7.2 V
1.5 A
1.5 V
-20 to 40ºC (-4 to 104ºF)
6-step, fully automatic
6 and 12 V (nominal)
All lead-acid (Wet, MF, Ca, AGM and Gel)
Charging: 5 to 40 Amp-hour
Maintenance: 5 to 200 Amp-hour
Natural convection
IP65
Dimensions (L x W x H)
Weight
2 15/16 x 3 7/8 x 9 1/16" (7.5 x 9.8 x 23 cm)
1 lb 3 oz (0.55 kg)