Figure 2-4. EWR6300 Mounting Bracket
1 Using the deployment guidelines described in the MEA Setup and Deployment User’s
Guide, locate an appropriate mounting pole such at a streetlight cobra arm or a metal
post. The mounting pole can be vertical, horizontal, or project at almost any angle.
2 Remove one of the C-Clamp Bracket bolts so that the bracket can be positioned around
the mounting pole. If necessary, remove the second bolt. When the two halves of the
Clamp Bracket are correctly positioned, reinstall the bracket bolts.
Note: The C-Clamp Bracket Assembly requires two 3 1/2 x 1/4 inch stainless steel bolts
to secure the C-Clamp to a mounting pole. Each bolt is supplied with (2) stainless steel
flat washers, (1) lock washer, and (1) stainless steel nut. The bracket hardware should
be installed as indicated in
Figure 2-5.