Spec Sheet

PAGE 3
PRODUCT SPEC SHEET
AP 621
AP 621 SPECIFICATIONS CHART (continued)
USER ENVIRONMENT AP 621 (INTERNAL ANTENNA) AP 621 (EXTERNAL ANTENNA)
Operating temperature: 32°F to 104° F/0°C to 40° C
Storage temperature: -40°F to 158° F/-40°C to 70° C
Operating humidity: 5%-95% (non-condensing)
Operating altitude: 8,000 ft./2438 m
Storage altitude: 15,000 ft./4572 m
Electrostatic discharge: +/- 15 kV (Air), +/- 8 kV (contact)
POWER SPECIFICATIONS
Operating voltage: 802.3af supply: 48 VDC @ 12.95W (typical), 36 VDC to 57 VDC (range)
Operating current: 270mA rms at 48V
Integrated Power-over-Ethernet support: Standards-based IEEE 802.3af
Typical Operational RMS Power Consumption: 10W (209mA at 48V)
MAXIMUM RADIO TRANSMIT POWER:
BAND SINGLE ANTENNA COMPOSITE TRANSMIT POWER DUAL ANTENNA COMPOSITE TRANSMIT POWER
2400MHZ +24 dBm +27 dBm
5200MHZ +20 dBm +23 dBm
ANTENNA PORT SPECIFICATON
Type: Integrated 2.4 GHz and 5.2 GHz Dual-Antenna Elements Two RP-SMA connectors for external antennas (not included)
Band: 2.4 GHz to 2.5 GHz; 5.180 GHz to 5.850 GHz (actual operating frequencies depend on regulatory rules and certification agency)
INTERNAL ANTENNA INFORMATION
REGULATORY
Product safety certifications: UL 60950, cUL, EU EN 60950, TUV and UL 2043 (external antenna)
Radio approvals: FCC (USA), Industry Canada, CE (Europe)
INTERNAL ANTENNA DESCRIPTION VALUES
Peak gain, 2.4GHz band 3.0dBi
Peak gain, 5.2GHz band 6.0dBi
Continued on next page...