User guide

6 - 18 MC909X User Guide
Universal Battery Charger (UBC) Adapter
This section describes how to use the UBC adapter to charge a spare battery.
The UBC can be used with a power supply as a standalone spare battery charger or it can be used with the
four station UBC2000 to provide charging to simultaneously charge up to four spare batteries. For additional
information about the UBC2000, see the UBC 2000 Universal Battery Charger Product Guide (p/n
70-33188-xx).
Figure 6-18
UBC Adapter
Inserting and Removing a Battery
Insert the battery into the battery well with the charging contacts facing down (over charging pins) and gently
press down on the battery to ensure proper contact.
To remove the battery, press the battery release and lift battery out of the well.
Battery Charging Indicators
To charge a spare battery using the UBC adapter, connect the power supply to the UBC, then insert the spare
battery. The spare battery begins charging automatically.
The UBC’s charge LEDs (see Figure 6-19) show the status of the battery charging in the adapter. Table 6-1
shows battery charging status indications.
The battery usually charges in three hours.
POWER
READY or STANDBY or FAU LT
CHARGING
(Green) (Flashing Yellow) (Solid Yellow)
(Solid Yellow)
UBC Adapter
Battery Release
Battery
Battery Well
CAUTION Use only a Symbol approved power supply output rated 15 VDC and minimum 1.5 A. Use of an
alternative power supply will void the product warranty and may cause product damage. See
Appendix C, Regulatory for the power supply regulatory compliance statement.