Technical data

Installation Instructions
http://www.mcg.mot.com/literature 1-21
1
The following circuits are protected by solid-state fuses that open during
overload conditions and reset themselves once the overload is removed:
LAN AUI
SCSI terminator
Remote reset connector
IndustryPack 5V
±12V
The
FUSES LED illuminates to indicate that all fuses are functioning
correctly. If a fuse opens, power must be removed for several minutes to
allow the fuse to return to a closed or shorted condition.
Serial Connections
The MVME172LX uses two Zilog Z85230 serial port controllers to
implement the four serial communications interfaces. Each interface
supports CTS, DCD, RTS, and DTR control signals as well as the TXD
and RXD transmit/receive data signals. Because the serial clocks are
omitted in the MVME172LX implementation, serial communications are
strictly asynchronous. The Z85230 is interfaced as DTE (data terminal
equipment) with EIA-232-D signal levels. The serial ports are routed to
four RJ-45 connectors on the front panel.
For additional information on the EIA-232-D interface, refer to the EIA-
232-D Standard.
Connection diagrams for the four serial ports on the MVME172LX are
provided in the following figures. These ports are connected to external
devices through cables connected to the front panel.