Technical data

2-1
2
2Startup and Operation
Introduction
This chapter provides information on powering up the MVME172LX
VME Embedded Controller after its installation in a system, and describes
the functionality of the switches, status indicators, and I/O ports.
For programming information, consult the MVME172 Embedded
Controller Programmer’s Reference Guide.
Front Panel Switches and Indicators
There are two switches (ABORT and RESET) and four LED (light-emitting
diode) status indicators (
FAIL, RUN, SCON and FUSES) located on the
MVME172LX front panel.
Table 2-1. MVME172LX Front Panel Controls
Control/Indicator Function
Abort Switch (
ABORT) Sends an interrupt signal to the processor. The interrupt is normally
used to abort program execution and return control to the debugger
firmware located in the MVME172LX Flash memory.
The interrupter connected to the ABT switch is an edge-sensitive
circuit, filtered to remove switch bounce.
Reset Switch (
RESET) Resets all onboard devices. Also drives a SYSRESET* signal if the
MVME172LX is system controller. SYSRESET* signals may be
generated by the Reset switch, a power-up reset, a watchdog timeout,
or by a control bit in the Local Control/Status Register (LCSR) in the
VMEchip2 ASIC. For further details, refer to Chapter 4, Functional
Description.