Technical data

PMC Interrupts
4-5
4
The lower two primary address bits AD(1:0) are 01 (binary)
The device number in AD(15:11) is 1_1111 (binary)
The function number in AD(10:8) is 111 (binary)
The register number in AD(7:2) is 00_0000 (binary)
The bus number in AD(23:16) is $01 (i.e., the value in the
Secondary Bus Number Register)
The bus command on C/BE# is a configuration write command
The 21150 translates the Type 1 Configuration command to a Special
Cycle and forwards the address and data unchanged. The transaction is
forwarded as a delayed transaction but the target response is not forwarded
back because Special Cycles result in a master abort. If more than one data
transfer is requested during a Special Cycle, the 21150 responds with a
target disconnect during the first data phase.
PMC Interrupts
The routing of interrupts from each PMC adapter is described in Table 4-2.
Figure 4-2 and Figure 4-3 show the overall routing back to the Raven chip
on the VME processor modules.
Table 4-2. PMC Interrupt Routing
Device on
Secondary Bus
(Hex)
Device
(PMC Adapter)
Interrupt Pin
PCI Interrupt
02 (PMC 1) INTA# INTC#
INTB# INTD#
INTC# INTA#
INTD# INTB#