User`s guide

38
Command Option Function
+VSM=
m,n,p,q
Specifies the voice compression parameters
m
options: Specifies the compression method
128 PCM
129 ADPCM
n
options: Specifies the sampling rate to determine
whether to compress
8000 8000 Hz
P
options: Parameter
p
specifies compression and
expansion of periods of silence. These
parameters are not implemented in Release 1.
0. You may leave them blank or enter the value
0.
0 Disable
q
options: Parameter
q
specifies compression and
expansion of periods of silence. These
parameters are not implemented in Release 1.
0. You may leave them blank or enter the value
0.
0 Disable
+VTD DTMF Tone Duration
+VTD
n
Generate tone for
n
/100 seconds;
n
=0-255.
Default=100.
+VTS DTMF Tone Generation Properties
+VTS accepts multiple options, separated by
commas, of any of the following types. Use
square and curly brackets as shown.
D Generate default DTMF Tone, default duration
(f,n) t
specifies a DTMF tone;
t
= 0-9
n
specifies tone duration
n
/100 seconds;
n
= 1-500
(f,g,n) f
and
g
specify a tone pair,
f
Hz and
g
Hz; in
the range
n
Specifies tone-pair duration
n
/100 seconds; n = 1-500
Examples: AT+VTS=4,{},[1000,1300,50],8.{*5},[,,100]5
This example specifies the following sequence:
1.Play DTMF 4 for the duration stored in + VTD
2.Play silence for the duration stored in +VTD
3.Play tone pair at 1000 Hz and 1300 Hz for 500
ms
4.Play DTMF 8 for a duration stored in +VTD
5.Play DTMF * for 50 ms
6.Play silence for 1 second
7.Play DTMF 5 for the duration stored in + VTD
+VTX Enter Voive-Transmission Mode
Notes: the speakerphone state does not have
to be reset after recording to the line or playing
a message to the line. The baud rate is not set
before the StartPlay and StartRecord
commands. The baud rate is not reset after the