OPERATION MANUAL OFFICE PRO 60 FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA BUSINESS REPLY MAIL POSTAGE WILL BE PAID BY ADRESSEE DENSO SALES CALIFORNIA, INC. 3900 VIA ORO AVENUE LONG BEACH, CA 90810-9969 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Technical Services Department DSCA P/N: LA990009-1219 GAC P/N: LA484007-1441 Third Issue: March 2003 Printed in the U.S.A.
10 12 18 24 60 LIMITED WARRANTY The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of any kind.
OPERATION MANUAL OFFICE PRO 60
ii
TABLE OF CONTENTS FOREWORD ............................................................................................ 1 Definition of Terms .......................................................................... 1 GENERAL WARNINGS & CAUTIONS .................................................... 2 INVENTORY ............................................................................................ 3 INSTALLATION .......................................................................................
iv
FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to assemble, install and operate the MovinCool Office Pro 60 portable air conditioning unit. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also find it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change without prior notice.
GENERAL WARNINGS & CAUTIONS • All electrical work, if necessary, should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. All electrical components replaced must be genuine MovinCool parts, purchased from an authorized reseller. • The proper electrical outlet for MovinCool units must be equipped with a UL approved ground-fault breaker to prevent electrical shock from the unit.
INVENTORY After unpacking your MovinCool unit, please check to make sure you have the following items: • Office Pro 60 MovinCool Unit (1) • Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
INSTALLATION Choosing an Installation Site CAUTION: Following are some precautions to consider before choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit. • Do not use the unit in areas where leakage of flammable gas may occur. • Do not use the unit in areas where it will be exposed to rain or water. • Do not use the unit in an atmosphere of excessively corrosive gas or vapor.
INSTALLATION (cont.) Moving the Unit Unlock the casters and push the MovinCool unit, using the side handles, to a flat, level surface and set the casters back to the LOCKED position.
INSTALLATION (cont.) Plugging in the Unit • Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. • Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. • Fully insert plug into the A/C outlet. WARNING: • If the power cord or plug is damaged, repair should only be performed by qualified electrical personnel.
FEATURES OP60 Features • An electronic control panel which allows the user to control the unit’s operation easily. • Dual fan speeds (either High or Low) in both COOL and Fan Only modes. • A digital display that indicates the Temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate. This is also the temperature the unit will try to maintain. The Temperature SET POINT can be adjusted by the SET TEMP buttons (▼/▲).
OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel. 5 4 6 TANK F AM C PM FULL SET POINT SET TEMP ROOM TEMP CLOCK/TIMER 3 HRS MIN FAN ON/OFF START TIME 2 END TIME SET CLOCK 1 SET COOL ON/OFF RUN PROGRAM Office Pro 60 ➀ COOL ON/OFF Button Activates/deactivates the COOL mode/ turns the unit off. ➁ FAN ON/OFF Buttons Activates/deactivates the HIGH or LOW fan mode.
OPERATION (cont.) Control Panel (Cont.) 7 SET TEMP 8 CLOCK/TIMER HRS MIN 12 FAN ON/OFF START TIME END TIME 11 SET CLOCK SET COOL ON/OFF RUN PROGRAM 9 10 Office Pro 60 ➆ Temperature Scale LED Illuminates to indicate the current temperatures being displayed are either in °C or °F; also used to display the clock when programming. ➇ AM/PM LED Illuminates to indicate AM or PM time of day. ➈ Program RUN Button Activates/deactivates a program.
OPERATION (cont.) Operating in COOL Mode ➀ The unit can be operated in COOL mode by pressing the COOL ON/OFF button (LED illuminates). NOTE: In COOL mode the unit can only be turned off by pressing the “COOL ON/OFF” button again, not by pressing the fan buttons. ➁ Change the fan speed by pressing the HIGH or LOW fan buttons. ➂ Change the temperature set point by pressing the SET TEMP buttons (▼/▲).
OPERATION (cont.) How to Set a Program ➀ Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. ➁ Setting an END TIME Press the Program SET button until the END TIME LED illuminates. Press the HRS and MIN buttons to set the END TIME. ➂ Setting the CLOCK TIME Press the Program SET button until the SET CLOCK LED illuminates.
OPERATION (cont.) How to Set a Program (Cont.) NOTE: • The unit will return to the previous mode if a program is turned off while it is running. • The Program RUN LED flashes while a program is running. It is illuminated continuously when the program mode is activated. • While a program is running, the program can only be stopped by pressing the Program RUN button. All other buttons are inoperable when a program is running. • The unit returns to the previous mode at the end of a program.
OPERATION (cont.) Operating Modes Office Pro 60 operates in 2 modes, FAN Only and COOL. When in FAN Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. • COOL Mode Office Pro 60 will operate in FAN Only mode for approximately 120 seconds before the compressor engages. (Time delay setting is 120 ±15 seconds.
OPERATION (cont.) Emptying the Drain Tank (If equipped) During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off. If a program is running, you must first press the Program RUN button. ➀ Open the drain tank lid. ➁ Pull the drain tank from the unit.
OPERATION (cont.) Drain Pump A drain pump is included to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. • When the water level drops below level (B), the drain pump will stop. B A NOTE: • If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation.
HOSE INSTALLATION Note: The OP60 is equipped with a 20 foot (6 m) hose. Connect the 20 foot (6 m) hose to the drain outlet spout and feed it through the grommet on the right hand side of the unit. DRAIN STEM DRAIN HOSE Note: Do not use more than 18 feet (5.5 m) of drain hose vertically. This is the maximum head (lift) of the Condensate Pump. DRAIN HOSE DRAIN HOLE When securing the drain hose to the highest vertical position (no more than 18 feet (5.
DAILY INSPECTION & MAINTENANCE Emptying the Drain Tank To empty the drain tank, refer to instructions, page 14. Cleaning the Air Filters Clean the air filters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required. A dirty air filter reduces air output resulting in a decrease of the cooling capacity. Filter Removal Method ➀ Turn the unit off, by pressing the COOL ON/OFF button. If a program is running, you must first press the Program RUN button.
DAILY INSPECTION & MAINTENANCE (cont.) Cleaning Method ➀ Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash with a neutral detergent. ➁ After the element has been cleaned, rinse with clean running water, allow to dry, then reinstall. FILTER In-Season/Off-Season Inspection & Maintenance ■ ■ In-Season ➀ Check the prongs and surface of the power cord plug for dust and/or dirt.
TROUBLESHOOTING Office Pro 60 Self-Diagnostic Codes Self-Diagnostic Codes will be displayed on the Control Board under the following conditions: F TANK C SET TEMP When the evaporator freezestat disengages the compressor. FL When the drain tank switch shuts off the unit (FULL TANK LED flashes). AS When unit disengages the compressor while the condensate pump is discharging water. HP When the high pressure switch disengages the compressor. LO Lowest temperature set point.
TECHNICAL SPECIFICATIONS ITEM/FEATURES OFFICE PRO 60 Rating Conditions dry bulb wet bulb humidity 95º F (35º C) 83º F (28.2º C) 60% Specifications power frequency line voltage power consumption current consumption power factor starting current power wiring 60Hz single phase 208/230V 7.
10 12 18 24 60 LIMITED WARRANTY The aforesaid warranty is the only warranty made by DENSO with respect to the Products and is in lieu of all obligations or liabilities on the part of DENSO for damages arising out of or in connection with the sale, use or performance of the Products, including, without limitation, any lost profits or any other consequential, incidental, special or exemplary damages of any kind.
OPERATION MANUAL OFFICE PRO 60 FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA BUSINESS REPLY MAIL POSTAGE WILL BE PAID BY ADRESSEE DENSO SALES CALIFORNIA, INC. 3900 VIA ORO AVENUE LONG BEACH, CA 90810-9969 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES Technical Services Department DSCA P/N: LA990009-1219 GAC P/N: LA484007-1441 Third Issue: March 2003 Printed in the U.S.A.