User`s manual

6-6 Smartio C104H/HS User’s Manual
b. Check hardware configuration of Smartio C104 Series board by IO-
IRQ.EXE. Then make sure the hardware configuration, including I/O
addresses for each port, Interrupt Vector, IRQ, is identical to that of the
driver.
c. The I/O addresses may conflict with other devices, please change another set
of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.
d. The board(s) is not plugged properly. Please make sure the board is seated
firmly in the expansion slot.
e. The slot for plugging the board is defective.
In this case, please try other slots until you find a good one.
f.
The board might be defective.
DOS
This section is specific for troubleshooting under DOS. For general problems and
solutions, please see the previous section, “General Troubleshooting”.
1. After executing SER-DRV.EXE, error message “None serial port found!
appears.
a. Make sure you’re using the right driver.
b. Check if the board is properly plugged into ISA/EISA bus slot.
c.
Check if the I/O address and IRQ settings in SETUP program are same as
the settings on board.