NE-4100-P Series User’s Manual First Edition, September 2006 www.moxa.com/product MOXA Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support support@moxa.com Worldwide: support@usa.moxa.
NE-4100-P Series User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright © 2006 MOXA Technologies Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Trademarks MOXA is a registered trademark of The MOXA Group. All other trademarks or registered marks in this manual belong to their respective manufacturers.
Table of Contents Chapter 1. Introduction ...............................................................................................1-1 Overview .............................................................................................................................. 1-2 Package Checklist................................................................................................................. 1-2 Product Features ..............................................................................
1 Chapter 1. Introduction The NE-4100-P Series embedded device server is a line of compact programmable modules that act as network enablers. NE-4100-P Series modules can be installed in or on a serial device to connect it to an Ethernet network, allowing you to gain network access to any electronic device that has a serial port. All NE-4100-P Series modules come equipped with built-in TCP/IP protocols for fast integration, saving you time and energy on programming.
NE-4100-P Series User’s Manual Introduction Overview NE-4100-P Series modules are a type of embedded device server or network enabler. The module may be installed in or attached to a serial device to make it accessible from a network. There are three types of module offered: drop-in (NE-4100T-P), RJ45 (NE-4110S-P, NE-4110A-P), and pin header (NE-4120S-P, NE-4120A-P). The last two letters of the model number indicates the serial signal supported by the module.
NE-4100-P Series User’s Manual Introduction Product Specifications NE-4100T-P NE-4110S-P, NE-4110A-P NE-4120S-P, NE-4120A-P System CPU 16-bit MCU RAM 1 MB Flash 2 MB LAN Ethernet 10/100 Mbps, pin headers Protection 10/100 Mbps, RJ45 10/100 Mbps, pin headers built-in transformer with 1.
2 Panel Layout and Pin Assignments Chapter 2. This chapter includes information about the panel layouts and pin assignments for NE-4100-P Series modules. The layouts and reference circuit diagrams for the evaluation boards are also covered. The evaluation boards are used for evaluation and development of applications for NE-4100-P Series modules.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4100T-P, NE-4100-ST The NE-4100T-P is a TTL-to-Ethernet drop-in module. It measures 45 × 36 mm, and has a dual-in-line, 26-pin design, making it easy to integrate with your serial devices. The NE-4100-ST is the evaluation board for testing NE-4100T-P modules and developing your own applications. Panel Layout NE-4100T-P Pin #1 45.00 mm 36.00 mm Pin #14 NE-4100-ST 149.00 mm Ethernet Port 99.
NE-4100-P Series User’s Manual LED Name DIO3 TXD0 RXD0 DTR0 CTS0 DSR0 DCD0 RTS0 TXD1 RXD1 Panel Layout and Pin Assignments LED Color red red red red red red red red red red LED Function Indicates that DIO is in “low” (0) status. Indicates that TXD0 has a signal. Indicates that RXD0 has a signal. Indicates that DTR0 has a signal. Indicates that CTS0 has a signal. Indicates that DSR0 has a signal. Indicates that DCD0 has a signal. Indicates that RTS0 has a signal. Indicates that TXD1 has a signal.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4100-ST Serial Port Pinouts (DB9 Male) Debug Serial Port (reserved) Pin Signal 2 3 5 RXD TXD GND RS-232 Port for Connecting Serial Devices Pin Signal 1 2 3 4 5 6 7 8 DCD RXD TXD DTR GND DSR RTS CTS 5 3 2 5 4 3 2 1 DIO Terminal Block D0 D1 D2 D3 Block Diagrams +5 VDC 1 MB SDRAM Customer's Device 2 MB Flash 80186 CPU 10/100M Ethernet PHY TTL Serial data UART0 (Tx, Rx, RTS, CTS, DTR, DSR, DCD) MAC Transformer 1.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4110S-P, NE-4110A-P, NE-4110-ST The NE-4110S-P is an RS-232-to-Ethernet server, and the NE-4110A-P is an RS-422/485-to-Ethernet server. Both models use an RJ45 connection and measure 57 × 40 mm. The NE-4110-ST is the evaluation board for testing NE-4110S-P and NE-4110A-P modules and developing your own applications. Panel Layout NE-4110S-P 1 2 57.00 mm 2 10 1 9 40.00 mm J1 14 13 J2 NE-4110A-P 1 2 57.00 mm 2 10 1 9 40.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4110-ST LED Indicators LED Name Power LED Color red green Ready steady off DIO0 DIO1 DIO2 DIO3 TXD0 RXD0 DTR0 CTS0 DSR0 DCD0 RTS0 TXD1 RXD1 red red red red red red red red red red red red red LED Function Indicates the power is on. Steady on: Power is on and NE-4110 is functioning normally. y Power is off, or power error condition exists. y IP address cannot be found in DHCP mode. y IP address conflict.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4110S-P and NE-4110A-P Ethernet Port Pinouts Pin Signal 1 2 3 6 Tx+ TxRx+ Rx- 1 8 RJ45 Port NE-4110S-P and NE-4110A-P DIO and LED Header Pinouts (J2) GND GND DIO0 DIO1 DIO2 DIO3 TxD1 14 12 10 8 6 4 2 13 11 9 7 5 3 1 VCC(+5V) VCC(+5V) 10M_LED 100M_LED Ready_LED Reset RxD1 NE-4110-ST Pinouts Debug Serial Port (reserved) Pin Signal 2 3 5 RXD TXD GND 5 3 2 RS-232 Port for Serial Devices Pin Signal 1 2 3 4 5 6 7 8 DCD RXD TXD
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments Block Diagrams NE-4110S-P Block Diagram +5 VDC 1 MB SDRAM 2 MB Flash Serial data (Tx, Rx, RTS, CTS, DTR, DSR, DCD) 10/100 M Ethernet PHY 80186 CPU UART0 MAC Transformer 1.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4120S-P, NE-4120A-P, NE-4120-ST The NE-4120S-P is an RS-232-to-Ethernet server, and the NE-4120A-P is an RS-422/485-to-Ethernet server. Both models use pin headers instead of RJ45 connectors. The NE-4120-ST is the evaluation board for testing NE-4120S-P and NE-4120A-P modules and developing your own applications. ATTENTION The NE-4120-ST is the same board as the NE-4110-ST but with an RJ45 jack and pin headers.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4120-ST Jumper 7 (J7) Jumper 9 (J9) 149.00 mm 1 2 Ethernet Port 5 3 3 9 10 1 2 2 Power Jack 1 99.00 mm 13 14 Jumper 10 (J10) Interface Selector Jumpers ON 1 DIP 2 3 4 DI/O Selector Jumpers DI/O Signal Setting Switches Reset Button Debug Serial COM Port Serial Port (RS-232) DI/O Terminal Block * JP2 is used to select RS-232 or RS-422/485 operation.
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments Pin Assignments NE-4120S-P Serial Header Pinouts (J1) NC CTS0 DSR0 DTR0 RxD0 10 8 6 4 2 9 7 5 3 1 NC RTS0 GND TxD0 DCD0 NE-4120A-P Serial Header Pinouts (J1) NC NC NC RxDTxD+ 10 8 6 4 2 9 7 5 3 1 NC NC GND RxD+ TxD- ATTENTION The symbols “B” and “A” are often used in place of “+” and “-”, respectively. ATTENTION For the 2-wire RS-485 interface, pin 3 is for Data+ (B) and pin 4 is for Data- (A).
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4120-ST Pinouts Debug Serial Port (reserved) Pin Signal 2 3 5 RXD TXD GND RS-232 Port for Serial Devices 5 3 2 Pin Signal 1 2 3 4 5 6 7 8 DCD RXD TXD DTR GND DSR RTS CTS 5 4 3 2 1 8 7 6 Serial and DIO Terminal Blocks TXD+ TXD- RXD+ RXD- SGND D0 D1 D2 D3 Data+ Data- Block Diagrams NE-4120S-P Block Diagram +5 VDC 1 MB SDRAM 2 MB Flash Serial data (Tx, Rx, RTS, CTS, DTR, DSR, DCD) 10/100 M Ethernet PHY 80186 CPU UART0 M
NE-4100-P Series User’s Manual Panel Layout and Pin Assignments NE-4120A-P Block Diagram +5 VDC 1 MB SDRAM 2 MB Flash RS-422/485 Signal 10/100 M Ethernet PHY 80186 CPU UART0 MAC Transformer 1.
3 Chapter 3. Getting Started This chapter includes information about installation of NE-4100-P Series modules for development and testing.
NE-4100-P Series User’s Manual Getting Started Wiring Precautions This section describes some important safety precautions that you should pay attention to before proceeding with any installation. ATTENTION Be sure to disconnect the power cord before installing or wiring the evaluation board. ATTENTION Determine the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
NE-4100-P Series User’s Manual Getting Started Installing the NE-4100T-P onto the NE-4100-ST Before using the NE-4100-ST evaluation board with the module, disconnect the power supply, network, and serial device. In the center of the evaluation board, there is a square with one white inverted triangle (shown as black in the figure) on one of its sides, and 2 rows of female sockets on the other two sides. The NE-4100T-P module also has a white inverted triangle on one of its sides.
NE-4100-P Series User’s Manual Getting Started Installing the NE-4120S-P, NE-4120A-P onto the NE-4120-ST The NE-4120S-P and NE -4120A-P modules are attached to the NE-4120-ST board using mounting screws that are provided with the board. When attaching the module to the board, make sure that the module is oriented so that the jumper banks on the module and the board are aligned as shown below.
NE-4100-P Series User’s Manual Getting Started Note that the RS-485 interface is selected on the evaluation board for the NE-4110A-P and NE-4120A-P modules, even when the module is operating in RS-422 mode. Please refer to Chapter 2 - Panel Layout and Pin Assignments for additional details. Circuit Pad for External Connection A circuit pad is provided on the right side of each evaluation board for the development of additional application circuits. 5V 3.
NE-4100-P Series User’s Manual Getting Started Connecting to the Network To connect to the network for testing and development purposes, the module should be installed onto its evaluation board. Make sure that the module is correctly installed onto the evaluation board, then plug the Ethernet cable into the RJ45 jack. For models NE-4100T-P, NE-4120S-P, and NE-4120A-P, the RJ45 jack is located on the evaluation board; for models NE-4110S-P and NE-4110A-P, the RJ45 jack is located on the module itself.
NE-4100-P Series User’s Manual Getting Started DI/O Selectable Jumper DI/O Mode DI DO 0 1 2 3 Digital Input 0 1 2 3 ON 1 DIP 2 3 ON: Low OFF: High Digital Input Signal Setting Switch 4 Digital Output DO0 DO1 DO2 DO3 Digital Output LEDs : Low : High DO0 DO1 DO2 DO3 DI/O Terminal Block DI/O Mode jumpers 0 through 3 correspond with DIO channels 0 through 3. The jumper’s position determines whether the corresponding channel is linked to a DIP switches or to an LED.
NE-4100-P Series User’s Manual Getting Started For channels in digital output mode, “Low” and “High” status is controlled from within the web console. When using a Digital Output LED as your output device, “Low” status will be expressed by the LED lighting up, and “High” status will be expressed by the LED turning off. Digital Output DO0 DO1 DO2 DO3 : Low : High Digital Output LEDs Digital Output LED Circuit Design The figure shown below is the digital output LED circuit design.
A Appendix A. Well Known Port Numbers This appendix is included for your reference. Listed below are port numbers that already have a well-established use. These port numbers should be avoided when assigning a port number to your NE-4100-P Series module; otherwise you may experience network problems. Refer to the RFC 1700 standard for Well Known Port Numbers or refer to the following introduction from IANA.
NE-4100-P Series User’s Manual Well Known Port Numbers TCP Socket Application Service 43 Whois (nickname) 49 (Login Host Protocol) (Login) 53 Domain Name Server (domain) 79 Finger protocol (Finger) 80 World Wide Web HTTP 119 Network News Transfer Protocol (NNTP) 123 Network Time Protocol 213 IPX 160 – 223 Reserved for future use UDP Socket Application Service 0 reserved 2 Management Utility 7 Echo 9 Discard 11 Active Users (systat) 13 Daytime 35 Any private printer serve
B Appendix B. Service Information This appendix contains information on how to obtain information or service from MOXA for your NE-4100-P Series embedded device server and other MOXA products.
NE-4100-P Series User’s Manual Service Information MOXA Internet Services Customer satisfaction is our top priority. To ensure that customers receive the full benefit of our products, MOXA Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates. The following services are provided: Technical support e-mail address support@moxa.com Website for product information http://www.moxa.
NE-4100-P Series User’s Manual Service Information Problem Report Form MOXA NE-4100 Series Embedded Device Server Customer name: Company: Tel: Fax: Email: Date: Select Product Model NE-4100T NE-4110S NE-4110A NE-4120S NE-4120A NE-4100T-P NE-4110S-P NE-4110A-P NE-4120S-P NE-4120A-P Serial Number:____________________________________________________________________________ Problem Description Please describe the symptoms of the problem as clearly as possible, including any error me
NE-4100-P Series User’s Manual Service Information Product Return Procedure For product repair, exchange, or refund, the customer must: z z z z Provide evidence of original purchase. Obtain a Product Return Agreement (PRA) from the sales representative or dealer. Fill out the Problem Report Form (PRF). Include as much detail as possible for a shorter product repair time. Carefully pack the product in an anti-static package and send it, pre-paid, to the dealer.