Manual

Installation Instructions and Owners Manual
Unvented LP-Gas Vent Free Room Heaters
11
push in or turn by hand, don’t try to repair it call
a quali ed service technician or gas supplier.
Force or attempted repair may result in a re or
explosion.
D. Do not use this appliance if any part has been
underwater. Immediately call a quali ed service
technician to inspect the appliance and to re-
place any part of the control system which has
been underwater.
LIGHTING INSTRUCTIONS
1. STOP! Read the all safety information included
with and on the side of heater.
2. Make sure the equipment shutoff valve is fully
open.
3. Push in gas control knob and slightly turn
clockwise to the OFF position (see gure 16).
4. Wait ve (5) minutes. Then smell for gas
including near the oor. If you smell gas, STOP!
Follow “B” in the safety information above. If
you do not smell gas, go to the next step.
5. Push in and turn control knob counterclockwise
to PILOT. Press in control knob for ve (5)
seconds.
Note: The rst time that the heater is operated after
connecting the gas supply, the control knob should
be depressed for about 30 seconds. This will allow
air to bleed from the gas system. This may take
longer in some installations
Figure 16.
6. With control knob pressed in, push down and
release the ignition button. This will light pilot. If
needed keep pressing igniter button until pilot
lights.
7. Keep control knob pressed in for (30) seconds
after lighting pilot. After 30 seconds, release
control knob.
If pilot does not stay lit, refer to Troubleshoot-
ing, pages 14 & 15. Also, contact a quali ed
service person of gas supplier for repairs.
If control knob does not pop up when released,
contact a quali ed service person or gas sup-
plier for repairs.
8. When the pilot is lit, turn control knob coun-
terclockwise to heating level. The main burner
should light.
9. To select the desired heat level, turn the
temperature setting knob counterclockwise to
between 1 & 5.
THERMOSTAT CONTROL OPERATION
FOR IR20LPT / IR30LPT: The thermostatic control
used simply turns on and off the burner.
FOR BF20LPT / BF30LPT: The thermostatic control
used modulates the ame size as the temperature gets
closer to set point, then it turns off the burner upon
reaching temperature.
The burner will cycle back on when room temperature
drops below the set temperature. The control knob can
be set to any heat level between 1 and 5. Selecting the
HI setting will cause the burner to remain on.
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF HEATER
1. Turn control knob clockwise to the OFF
position.
2. Turn off all electrical power to the appliance if
servicing is to be preformed.
3. Turn off equipment shutoff valve.
SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)
1. Turn control knob clockwise to the PILOT/IGN
position.
INSPECTING BURNER
Check pilot ame pattern and burner ame pattern
often.
PILOT FLAME PATTERN
Figure 17 shows a correct pilot ame pattern and
incorrect pilot ame pattern. The incorrect pilot ame
pattern is not touching thermocouple. This will cause
the thermocouple to cool. When the thermocouple
cools, the heater will shut down. If pilot ame pattern is
incorrect, as shown in Figure 17:
Turn heater off (see To Turn OFF Gas to
Appliance, above.
See Troubleshooting, pages 14-15.
Ignitor Button
Control Knob
Figure 17
Correct pilot position. Incorrect pilot position.