AromaSteam Installation Sheet

mr
.
steam
®
AromaSteam Operation and Installation Instructions
______________________________________________________________________________________________
___________________________________________________________________________________________________________________________________________
2017 © Sussman-Automatic Corporation I Mr.Steam and des., A Lifetime of Pleasure, AromaFlo, AudioWizard, AutoFlush, AutoSteam, Butler Package, ChromaSteam, Clean Steam...Every Time, Club
Therapy, Digital 1, Express Steam, From Bathroom to Spa, HomeWizard, iButler, iGenie, iSizing, iSteam, iSteam/Plus, iSteamTV, iTempo, iTempo/Plus, Making Wellness a Way of Life, MusicTherapy,
MySteam, Spa Package, Smart Sizing, Steam Genie, Steam in a Box, Steam on Demand, Steam@Home, SteamStart, SteamStop, SteamTherapy, Sussman, The Intelligent Steam bath, Valet Package, Virtual
Spa System, Voice Genie and Voice Wizard are registered trademarks of Sussman-Automatic Corporation.
PUR
100402 2.17
8
TROUBLESHOOTING
T
O AVOID ELECTRIC SHOCK,
DISCONNECT POWER TO PUMP BEFORE SERVICING
Metering pump does not prime
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid, if necessary.
3. Check for air bubbles in the suction hose or the pump head.
To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves, if necessary.
5. Check foot valve in container for contamination. Rinse foot valve
under clean water.
Metering pump does not inject oil into steam
room
1. Check if voltage is available.
2. Check liquid level in scent container. Replenish liquid if necessary.
3. Check for air bubbles in the suction hose or the pump head.
To eliminate air bubbles see: Priming Pump.
4. Check valves for contamination. Clean valves, if necessary.
5. Check foot valve in container for contamination. Rinse foot valve
under clean water.
6. Check the pressure hose for kinking or jamming. Straighten or
replace.
7. Check if liquid is freely flowing through the atomizing nozzle
when the metering pump is energized. Apply compressed air
through the atomizing nozzle. Attach the compressed air at the
point of connection of the pressure hose.
8.
Ensure the pump has been powered up. See page 7.
Metering pump oil delivery too much or too little
The AromaSteam system has been factory set to deliver
a suitable amount of aromatic oil into a typical sized steam room.
Please contact the MrSteam Technical Service Department before
changing this setting. See page 7 for instructions on adjusting the
amount of oil delivery.
Contact the MrSteam Technical Service Dept. at (800) 76-STEAM
(East coast) or (800) 72-STEAM (West Coast) for assistance or
additional information.
Dimensions: 7.5"W x 4.5"H x 4.5"D
Weight: 5 pounds
Motor voltage 120VAC, 50/60 Hz
Current Draw 0.5 Amps
________________________________________
4.5”
7.5”
TECHNICAL SPECIFICATIONS
LIST OF SPARE PARTS
Description Part No.
Pump Head 104239
Pressure/Suction Hose 104255
(
ordered by the foot
)
Eucalyptus oil, 1 liter MS OIL 1
Lavender oil, 1 liter MS OIL 2
Evergreen oil, 1 liter MS OIL 3
Energizing Mint oil, 1 liter MS OIL 4
Breathe oil, 1 liter MS OIL 5
Atomizing Nozzle 104240
Oil Injector 103983
Foot Valve 104241
Fitting (Fig.1) 104250
WARNING
!
WARRANTY:
To view or download the
MrSteam Control Warranty and register your
product go to:
blog.mrsteam.com/wr
WARNING
!