Generators Installation Sheet

I N S T A L L E R
3
If acrylic, fiberglass or other non-heat resistant
materials are used as part of the steam room enclosure. Consult with
the material manufacture and see pg. 7, “Installing the Steamhead"
for additional details.
IMPORTANT NOTES:
This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. Do not
discard this document.
The following general information should be used in conjunction
with consultations with an architect, designer and contractor in
determining factors necessary in providing a suitable and safe steam
room.MrSteam steam generators are intended to be operated with
MrSteam iSteam
®
, AirTempo
®
, iTempo/Plus
®
, iTempo
®
Home Wizard
®
and iGenie
®
controls only, and are to be installed strictly in accor-
dance with the specific instructions contained in this manual and as
supplied in the manuals provided with the controls or accessories.
Never use damaged equipment, doing so may
result in an inoperative or hazardous installation.
Discontinue use of the steam generator and control if the steam
generator or control are damaged or otherwise not functioning
properly. Doing so may result in an inoperative or hazardous
installation
ELECTRICAL SHOCK HAZARD. MrSteam steam generators are
connected to 240V line voltage and contain live electrical
components. All installation and service to be performed by
qualified and licensed electricians and plumbers only. Installation
or service by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous condition.
The MS series of steam generators are for residential use only.
Commercial or other nonresidential applications void the warran-
ty and may adversely affect product performance and may repre-
sent a safety hazard.
The peel and stick warning label located in the
manual provided with the steam bath generator is an essential
part of providing a safe environment for steam room users. The
peel and stick warning label must be applied to the wall of the
shower or steam enclosure, at a point that is visible to all users.
Failure to install this sticker may result in serious injury or death.
The location where this owner's manual is kept shall be written
in the space provided on the label using permanent ink. For a
replacement warning label contact MrSteam customer service
at 1-800-76-STEAM or hello@mrsteam.com
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for
shipping damage. In the event of shipping damage, please
contact the carrier for claim information. Our
customer service department can assist you with any
missing or damaged parts.
Read these instructions before installation or service.
Although this MS steambath generator has been fully quali-
fied for shipment by MrSteam
®
, the following must be
reviewed for proper, safe and enjoyable steam bathing:
1. Verify that the model and accessories specifications are
correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized for
the steambath room. Pay particular attention to room vol-
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full
walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for
steam containment.
3. To prevent slip and fall hazards non-skip
strips must be installed on the steam room floor.
4. Check the suitability of any materials with the
manufacturer. Walls and ceilings must be constructed
of water-resistant, non-corrosive surface, such as tile,
marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of
condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices
should be installed inside the steam room.
8. Steam room tile construction information is available
from the Tile Council of America, Inc. by purchasing
the TCA Handbook for Ceramic Tile Installation.
Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be
double paned and tempered safety glass.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
ume and construction. If any questions, please refer to
MrSteam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s
size, requiring a generator larger than one based only
on the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing
servicing, and its distance from the steam room must all
be considered before final installation.
5. Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual
of all controls and accessories available at
www.mrsteam.com technical downloads.
6. Record the serial number of the steam generator in the
space provided in the table of contents of this manual.
CAUTION
!
mr
.
steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
Not Actual Size
WARNING
!
WARNING
!
WARNING
!