Instructions

Instruction Manual -
Time switch
en
Connection diagram
11 127 8 91 2 3
A B C
17 18
D
14 15
10 16
6 13
Ext1
4
L
~
+
5
N
~
-
DCF
GPS
* * *
OUTPUT
12V DC
80 mA
The installation and assembly of electrical
equipment must be only carried out only by a skilled
Person! Otherwise fire danger or danger of an
electric shock exists!
Connect the supply voltage/frequency as stated on
the product label!
Warranty void if housing opened by unauthorised
person!
The electronic circuit is protected against a wide
range of external influences. Incorrect operating
may occur if external influences exceed certain limits!
1. Safety instructions
The device can be used in following applications: Illumination of private and
industrial areas, street and shop-window lightening, regulation of air
conditioning, flushing, motors, pumps, plants and machinery as well as to
simulate presence etc.
Operate the device in a dry room only.
The device is not qualified for security relevant tasks such as emergency
doors, fire protection equipment
2. Intended use
See device
AgSnO
AgNi
IP 20 nach DIN EN 60529
-30° ... +55°
1 BSTU
2
4 kV
DIN EN 60730-1/DIN EN 60730-2-7
Ideal for modern lamps
2
Supply voltage
Contact material (110-230V AC)
Contact material (12-24V AC/DC)
Type of protection
Permitted ambient temperature
Mode of operation
Degree of contamination
Rated surge voltage
Standard
CFL, LED
3. Technical data
DIN-rail mounting product:
4. Battery
c
Defective wire between antenna and time switch (No antenna symbol
visible / The oscillating crystal is used as time base)
c
Reception is not possible if severe interference is present (Permanent
flashing of the symbol / The oscillating crystal is used as time base)
Antenna symbol (LCD) flashes for approx. 3 minutes
Connect supply voltage
Connect the antenna as indicated by the connection diagram
Disconnect power supply voltage
The time switch is prepared for use with a radio receiver
(DCF/GPS) prepared.
The radio receiver is not included.
5. Installation of the radio receiver
If required, date, time and daylight savings time mode can be adjusted
also by pressing r q -buttons and a subsequent confirmation with s.
The current date and time is already programmed and European
daylight savings time is activated.
Select the desired language by pressing r q-buttons and confirm it by
pressing s . (Remark: By pressing t you move one step backwards
rom the current position).
Press s / t button to wake it up.
The time switch is delivered in sleep-mode, the display is switched off.
6. Initial operation
f
OK
f
0
12
24
18.06.2020
9:28
00
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
MONday
PROGRAM
ADJUSTMEN
TS
OPTIONs
END
PROGRAM
New
PROGRAM
query
PROGRAM
edit
PROGRAM
delete
LN
PROGRAM
Simulation
PROGRAM
END
Date-T
ime
Summertim
me
Astro
DatA
LANGUAGE
N
FACTORY
DEFAULTS
END
COUNTER
pin-code
EXTRA
sWITCHING
CyCLE
RANDOM
inPUT
END
7. Menu overview
Current state is based on a switching time with cycle function.
L
Element within sub-menu “program delete”.
Z
Current state is based on a switching time with pulse function.
I
Current state is based on a manual over-ride. The state is permanent until terminated manually.
P
Current state is based on a manual over-ride. The state will be cancelled with the next programming step.
H
Standard programming step
U.
Days of the week Monday, Tuesday, ... Sunday; The underscores indicate if the program is active for the days above.
1234567
Channel is switched OFF
y
Channel is switched ON
x
8. Symbol legend
2. To confirm the selection or the entered data.
1. To activate the time switch when operated without power supply.
f.
2. Automatic-mode: A push longer than 3 sec. = Permanent switching status.
1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs.
D
C
BA
2. To scroll through a choice.
1. To adjust the flashing digit.
2. To revert to the beginning of the current (sub-) menu.
f.
1. To access the Enter-mode (program, adjustments, options) from the automatic-mode.
9. Key function
With r q the choice changes from END to ConTinue. By confirming
ConTinue mit s the time switch returns s to the beginning of the current
(sub-) menu.
After completion of a (sub-) menu confirming END with s will return the device
into the automatic-mode.
To revert one step or one level back while in the Enter-Mode press t.
The time switch is programmable without external power supply after pressing
the s-button.
10. Handling advice
By pushing -buttons a manual switch of the
channels take place. The resulting switching status is
marked with the hand-symbol and remains until the
next programming step occurs (temporary over-ride).
H
11. Channel ON / OFF
12. Permanent
P
By pressing the corresponding channel button for
more than 3 sec. the channel is permanently switched
ON or OFF. The status remains until the next manual
switching occurs (> 3 sec.) (permanent over-ride).
f
OK
f
0
12
24
18.06.2020
9:28
00
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
MONday
PROGRAM
PROGRAM
NEw
Channel A
Standard
OKM
f
OK
f
0
12
24
PROGRAM
13. b) Standard weekly program
Standard
f
OK
f
0
12
24
Program
new
f
OK
f
0
12
24
channel ...
OK
M
Special
Program
Permanent
END
ON
CYCLE
OFF
PULSE
END
Monday
yes
T
uesday
yes
Wednesday
yes
Thursday
yes
Friday
yes
Saturday
No
Sunday
N
o
1
2
3
4
5 6 7
time
hour
0
00
:
1
2
3
4
5 6 7
time
Minute
0
00
:
1
2
3
4
5 6 7
Next
Switching
END
OK
OK
OK
M
If you want to proceed with programming, confirm Next Switching with s.
To leave the programming menu change with r q to End and confirm with s.
Adjustment of the time: Hours r q and s, Minutes r q and s.
Within this level you activate the days of the week (1…7) on which the switching time should happen. With r q -buttons you
activate yes or deactivate No the corresponding date. Confirm each date with s.
For regular switching times choose ON or OFF with r q -buttons and confirm with s.
If you want to program a standard weekly switching time (ON / OFF) confirm Standard with s.
13. c) Example for the programming of STANDARD switching times (ON and OFF)
f
OK
f
0
12
24
PROGRAM
14. Special program Entry (within yearly time switches)
Standard
f
OK
f
0
12
24
Program
new
f
OK
f
0
12
24
Channel ...
OK
M
Special
Program
Permanent
END
SP
01
END
OK
M
SP
10
SP
Entry
END
SP
activation
SP
on
SP
cYcLe
SP
off
END
SP
pulse
OK
MONday
yes
time
hour
0
00
:
time
Minute
0 00
:
pulse
Minute
0
00
:
pulse
Second
0
00
:
Next
Switching
END
The yearly function of the switch is realised by special (weekly) programs which can be called up by date. Up to
10 special (weekly) programs can be entered (sP 01 SP10).
Execution of the Special program only after activation by date (SP activation see point 15).
c
Some rules for the programming of Special programs
Define the program number in which the new step will be an element before a new switching step is entered.
(SP 01 – SP 10)
The number of switching times which can be programmed in each special program is only limited by the total
number of free memory locations: (SP on, SP off, SP cycle, SP pulse)
The dates/times of the year during which the special program should be applied can be entered within the
activation menu (point 15).
Each special program can be activated as often as there are memory locations are available (point 15).
During the activation dates of special programs only switching steps of the special program with highest priority
will be executed. Remaining special and standard programs are disabled.
Please note the priorities of the different switching programs (point 23).
f
OK
f
0
12
24
PROGRAM
15. Special program activation by date (within yearly time switches)
Standard
f
OK
f
0
12
24
Program
new
f
OK
f
0
12
24
Channel ...
OK
M
Special
Program
Permanent
ENDE
SP
01
END
OK
M
SP
10
SP
Entry
END
SP
activation
START SP
Month
ST
ART SP
day
ST
ART SP
hour
START SP
Minute
Next
switching
END
A special program will only be executed if it is activated. You can choose the special program
(SP 01 – SP 10), the start/end time (date and time) for activation and additionally following options:
FUNcTION STANDARD: Special program will be applied each year fixed to the entered dates and times
Function easter: The time switch takes into account the yearly shift of the Easter holiday for
following years and corrects the activation dates. (For programs relative to Easter, Pentecost Carnival,
Ascension,...)
Function with year: Special program is executed once by date with year and time (“century function“
- requires 2 memory locations)
END SP
Month
End SP
day
End´ SP
hour
End SP
Minute
Function
Standard
Function
easter
Function
with year
END
23
59
:
N
Y
A
D
DCF / GPS: The time switch receives the time signal from the time signal antenna.
c
c
Additionaly at yearly time switches
F
Switching function / switching time with Easter function: The switching function takes into account the yearly shift of Easter holiday
for future years and changes the date of the switching program accordingly.
e
Is displayed if the corresponding channel is activated by the external input.
Current state is based on a switching time with astro function.
S
The time switch is locked; to unlock the device the PIN has to be entered.
13. a) Programming menu
Channel B
Channel ...
End
Special
Program
PERMANENT
End
OKMOKMM OK
* depends on model
t
r
q
s
D
C
BA
s
1. To activate Bluetooth when time switch is active.
END
www.hugo-mueller.de
Hugo Müller GmbH & Co KG, Karlstraße 90, DE-78054 VS-Schwenningen
[SC88.x0pro4 / SC98.x0pro4]
BA SC88 SC98pro4 HM; de,en -24132- 2020.06V01
12V
-
+
DCF
DC
OUTPUT
INPUT
SC 98.40 pro4
0
1
2
24
SP
SP
SP
SP
06.07.2020
MONT
AG
9:28
00
GPS
DCF
INPUT
GPS
+