7a. If you selected Remote Access Selection from the Asynchronous Port Function screen, the
Remote Access screen displays.
You must define the location of your remote user account database by selecting Use
Local Client List
or Use RADIUS Server.
Figure 7 – Remote Access with Default Screen: Use Local Client List
Use Local Client List
Note: The Local Client List allows you to add a maximum of 64 users.
The Local Client List is an authentication database of user names, passwords and
dial-in options for each remote user. Enter the following information for each client:
User Name to authenticate the remote dial-in user.
Password to authenticate the remote dial-in user. Passwords are limited to 16
characters.
Re-enter the remote dial-in user’s password for
Verification.
Select one of the following three Callback Types for each remote client:
No Callback: This option allows the remote user to immediately connect to
the network after being authenticated.
No Callback is the default.
Fixed Callback: This option allows you to specify a fixed callback telephone
number for the user. After the PPP negotiation, the device will disconnect,
and then callback the telephone number you entered in the callback