- Multi-Tech Broadband Router User Guide

Chapter 5 – RouteFinder Manager
RouteFinder RF500S User Guide 71
Assign Remote Site an IP Address
Check the Remote IP Address box to active the field, and enter the Remote IP Address
the remote site will use.
Allow Remote Dial-In
Check the Allow Remote Dial-in box if you want to allow a remote site to dial-in to this
network. When you click the
Remote Authentication Settings button, the Remote
Authentication Settings
screen displays (see below).
Callback Settings
Callback Settings allow you to establish a connection with your ISP from a remote site.
Check the Callback Settings box to select one of three callback options:
1. No Callback
2. Trigger (ISP) Server Connection
- The RouteFinder will establish a connection with
the ISP server after a remote user dials into the asynchronous port. The device can
be triggered to automatically establish a connection with the ISP in one of two
ways:
The ISP server is dialed after the RF500S receives a PPP (modem) connection
from a remote user.
The RF500S makes the connection to the ISP server after receiving a regular
telephone call. The remote user calls the RF500S async port to trigger the
connection to the ISP server.
3.
Remote Callback - After dialing, the RF500S hangs up and waits for the remote
site to callback. You must enter the callback telephone number (the telephone
number the device should call) in the
Tel Number field.