Cut Sheet

Product Codes, Trade Sizes, Conductors, Packaging & Weights
Grounding Approx. Armor
Product Code Conductor Length (feet) Weight/1000 Minimum
Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)
2105S42-80 2105S60-80 12-2 (black, white) 12 (solid green) 250' 1000' 135 0.530
2105S42-84 2105S60-84 12-2 (red, white) 12 (solid green) 250' 1000' 135 0.530
2105S42-85 2105S60-85 12-2 (blue, white) 12 (solid green) 250' 1000' 135 0.530
2106S42-80 2106S60-80 12-3 (black, red, white) 12 (solid green) 250' 1000' 170 0.565
2110S42-80 2110S60-80 12-4 (black, red, blue, white) 12 (solid green) 250' 1000' 205 0.625
2108S42-80 2108S60-80 10-2 (black, white) 10 (solid green) 250' 1000' 215 0.600
2108S42-84 2108S60-84 10-2 (red, white) 10 (solid green) 250' 1000' 215 0.600
2108S42-85 2108S60-85 10-2 (blue, white) 10 (solid green) 250' 1000' 215 0.600
2109S42-80 2109S60-80 10-3 (black, red, white) 10 (solid green) 250' 1000' 260 0.645
2111S42-80 2111S60-80 10-4 (black, red, blue, white) 10 (solid green) 250' 1000' 310 0.715
2159S42-80 2159S60-80 12-2 Stranded (black, white) 12 (solid green) 250' 1000' 145 0.530
NOTE: All dimensions and weights are subject to normal manufacturing tolerances. Other conductor colors available by special order.
WARNING: DO NOT RE-IDENTIFY CONDUCTOR COLORS
MC
15
800-757-6996 www.afcweb.com
AFC Cable Systems
MC-Lite
®
IG Isolated Ground
Technical Specifications
Specification Description
Specification MC-Lite® IG ColorSpec ID System
®
Armor Interlocking Aluminum Strip
Conductors Solid/Stranded Copper
Conductor Insulation THHN/THWN
Assembly Covering Polypropylene Tape
Maximum Temperature Rating 90°C (dry)
Grounding 2 grounding means — 2 grounding
conductors: one solid green,
one green with yellow stripe
Neutral Conductor White for 120V
Maximum Voltage Rating 600V
References & Ratings
U.L. 83, 1479, 1569, 1581, File Reference E80042
NEC 230.43, 250.118, 300.22(C), 392, 396, 330, 518, 520, 530, 645
Cable Tray installations per NEC
Federal Specification A-A-59544 (formerly J-C-30B)
Meets all applicable OSHA and HUD Requirements
U.L. Classified 1, 2 and 3-hour through-penetration Fire Wall
Environmental Air-Handling Space installation
Cable Tape
Copper
Conductors
Green
Insulated
Copper
Grounding
Conductor
Nylon Thermoplastic
THHN Insulation
Aluminum Interlocked Armor
Color-Trak ID System
®
Additional
Green
Grounding
Conductor
with Yellow
Stripe
Additional black, and green
stripe denotes 2 conductor
cable with additional ground
Additional black, red and green
stripes denote 3 conductor
cable with additional ground
Additional black, red, light blue
and green stripes denote 4
conductor cable with additional
ground
Additional red, white and
green stripes denote special 3
conductor cable with additional
ground
Additional light blue, white and
green stripes denote special 3
conductor cable with additional
ground
AFC’s ColorSpec ID System
®
AFC0704_Cbl Cat Body 4/10/07 10:20 AM Page 15

Summary of content (1 pages)