User manual

Technical Data TPS1200 203
There are no special prisms required for ATR or for PS.
Electronic Guide
Light EGL
Automatic
corrections
The following automatic corrections are made:
360° Mini prism,
GRZ121
+30.0 yes not recommended
Reflector tape S,
M, L
+34.4 yes no
Reflectorless +34.4 no no
Type Additive Constant
[mm]
ATR PS
Working range: 5 - 150 m
Positioning accuracy: 5 cm at 100 m
Line of sight error Vertical index error
Tilting axis error Standing axis tilt
Earth curvature Refraction
Circle eccentricity ATR zero point error
Compensator index error