User`s guide

Page 133
9.7.21 User defined checkpoint
This screen is displayed after selecting a USRDFN checkpoint for update or
add.
GSM280C Monitor system operations 12-02-01 12.00.00
Ver 6.13 USERID SYSNAME
Type values and press Enter
Checkpoint type . . . . . . . *USRDFN
Description . . . . . . . . . User defined checkpoint________
Schedule number . . . . . . . 1 F4=List
Operational message receiver . *SYS______
Check cycles bypass value . . 5
User written program name . . USERPGM___
Library name . . . . . . . . . USERLIB___
F12=Cancel
User defined checkpoint
Checkpoint Description
Descriptive text of the checkpoint.
Schedule number
Number of the schedule that controls when this checkpoint will run.
Operational message receiver
Name of the user or distribution group that shall receive messages created
by this checkpoint. Value *SYS directs those messages to the user specified
when using the main menu item 10 for this system.
Check cycle bypass value
This field controls if the checkpoint shall run every time the monitor
operations program runs. In order to save system resources it might be
desirable to bypass some check cycles. The value controls how many cycles
in a row to be bypassed before the checkpoint is run again.
For the *USRDFN checkpoint the default value is 5, the checkpoint bypasses
five cycles before it runs the next time.
User written program name
Name of the user written program.
See chapter Sample programs for more information on how to write a user
checkpoint program.
Library name
Name of the library containing the user written program.