User`s guide

Page 93
9.4.6 GSM Module via communication server
This screen will be displayed if connection type 5 is selected.
GSM2406 Communication config descriptions 12-02-01 12.00.00
Ver 6.13 USERID SYSNAME
Type values and press Enter
Configuration name . . . . . . GSMT34
Configuration description . . Asynchronous GSM device
Configuration type . . . . . . 3
Connection type . . . . . . . 4
Configuration name . . . . . . GSMT35
Configuration description . . GSM module communication svr
Configuration type . . . . . . 3
Connection type . . . . . . . 5
IP address comm server . . . . 192.168.1.26
Port number communication svr 8000
Port number comm svr ctl job . 8001
Device type . . . . . . . . . ETM9300
SIM card PIN code . . . . . . 0000
Network ID . . . . . . . . . . 240-01 F4=List
Service center address to use 1
F12=Cancel
GSM module
IP address
Specify the IP address assigned to the communication server.
Port number communication server
TCP/IP port number for communication with the server.
Port number communication server control job
TCP/IP port number for communication with the communication server
control job.
Module type
The following GSM module types are supported:
A1 Siemens A1
ETM9200 ETM 9200
ETM9300 ETM 9300
ETM9350 ETM 9350
GM12 Ericsson GM12
GM22 Ericsson GM22
M1 Siemens M1
TC35 Siemens TC35
TC35i Siemens TC35i
POCKETGSM Digicom PocketGSM