Owner`s manual

43
Chapter 4 - AT Commands, S-Registers and Result Codes
S13
Remote Configuration Escape Character
Unit: ASCII Character
Range: 0-127
Default: 37 (
% sign
)
Description: Defines the remote configuration escape character.
S17
Changing Break Time
Unit: 10 mSec.
Range: 0-2.5 sec
Default: 250
Description: S17 defines the break time (space) to local PC.
S24
PBX/CBX Disconnect Drop Time for DSR/CTS/CD
Unit: 50 mSec.
Range: 0-255
Default: 20
Description: Defines DSR/CTS/CD dropout time. The default of 20 equals
one second.
S25
DTR Dropout Time
Unit: 100 mSec.
Range: 0, 1 through 255
Default: 0
Description: Defines DTR dropout time. 0 default equals 50ms.
S26
Failed Password Attempts
Unit: 1 failed attempt
Range: 0-255
Default: 0
Description:Counts the number of times there has been a failed password attempt.