Specifications

Chapter5Troubleshooting
MT9234ZBAUSBUserGuide 22
TheModemDoesn’tWorkwithCallerID
CallerIDinformationistransmittedbetweenthefirstandsecondrings,soifautoansweristurnedoff(S0=0)
orifthemodemissettoanswerafteronlyonering(S0=1),themodemdoesnotreceiveCallerIDinformation.
Checkyourinitializationstring,andifnecessarychangeitto
setthemodemtoanswerafterthesecondring
(S0=2).
MakesurethatyouhaveCallerIDservicefromyourtelephonecompany.
FaxandDataSoftwareCan’tRunattheSameTime
Onlyoneapplicationatatimecanaccesscommunicationsdevices.InWindows2003andlater,youcanhavedataandfax
communicationapplicationsopenatthesametime,buttheycannotusethesamemodematthesametime.
TheModemDialsButCannotConnect
TherecanbeseveralreasonstheZBAfailstomakeaconnection.Possibilitiesinclude:
lackofaphysicalconnectiontothetelephoneline.
awrongdialtone.
abusysignal.
awrongnumber.
nomodemattheotherend.
afaultymodem,computer, orsoftwareattheotherend.
incompatibilitybetweenmodems.
Youcannarrowthelistofpossibilitiesbyusingextendedresultcodes.Extendedresultcodesareenabledby
default.Iftheyhavebeendisabled, enterATV1X4andpressEnterwhileinterminalmode,orincludeV1X4inthe
modem’sinitializationstring.Whenyoudialagain,themodemreports
thecall’sprogress.
IfthemodemreportsNODIALTONE,checkthatthemodem’stelephonelinecableisconnectedtoboththe
modem’sLINEjack(notthePHONEjack)andthetelephonewalljack.Ifthecablelookssecure,tryreplacingit.
Ifthatdoesn’twork,theproblemmightbeinyourbuilding’stelephone
installation.Totestthebuilding
installation,plugatelephoneintoyourmodem’stelephonewalljackandlistenforadialtone.Ifyouheara
dialtone,yourmodemmightbeinstalledbehindacompanyphonesystem(PBX)withaninternaldialtone
thatsoundsdifferentfromthenormaldialtone.
Inthatcase,themodemmightnotrecognizethedialtone
andmighttreatitasanerror.CheckyourPBXmanualtoseeifyoucanchangetheinternaldialtone;if you
can’t,changeyourmodem’sinitializationstringtoreplaceX4withX3,whichcausesthemodemto
ignoredial
tones(note,however,thatX3isnotallowedinsomecountries,suchasFranceandSpain).
IfthemodemreportsBUSY,theothernumbermightbebusy,inwhichcaseyoushouldtryagainlater,orit
mightindicatethatyouhavefailedtoadda9,prefixtothephonenumberifyoumustdial9foranoutside
line.
Ifyoumustdial9togetanoutsideline,theeasiestwaytodialitautomaticallyistoincludeitinthemodem’s
dialprefix,e.g.,ATDT9,.Notethecomma,whichinsertsapausebeforethenumberisdialed.Byinserting9,
intothedialprefix,youdonot
havetoincludeitineachdirectoryentry.
TochangethedialprefixinWindows98HyperTerminal,selectCallfromtheCallmenu,clickDialing
Properties,andtype9inthelocalandlongdistanceboxesinHowIdialfromthislocation.
IfthemodemreportsNOANSWER,theothersystemhasfailedtogooffhook,oryoumighthavedialeda
wrongnumber.Checkthenumber.