Datasheet

Reference only
13 / 17
No. Item Specification Test method
14 Flame test The capacitor flame discontinue
as follows.
The capacitor should be subjected to applied flame
for 15 s. and then removed for 15 s until 5 cycle.
15 Passive flammability The burning time should not be
exceeded the time 30 s.
The tissue paper should not
ignite.
The capacitor under test should be held in the flame
in the position which best promotes burning.
Time of exposure to flame is for 30 s.
Length of flame : 121mm
Gas burner : Length 35mm min.
Inside Dia. 0.50.1mm
Outside Dia. 0.9mm max.
Gas : Butane gas Purity 95% min.
16 Humidity
(Under steady
state)
Appearance No marked defect.
Set the capacitor for 50012 h at 402C in 90 to
95% relative humidity.
Post-treatment : Capacitor should be stored for 1 to
2 h at *
1
room condition.
Capacitance
change
Char. B : Within 10%
Char. E : Within 15%
D.F. 5.0% max.
I.R.
3 000M min.
Dielectric
strength
Per item 3
17 Humidity loading Appearance No marked defect.
Apply the rated voltage for 50012 h at 402C in
90 to 95% relative humidity.
Post-treatment : Capacitor should be stored for 1 to
2 h at *
1
room condition.
Capacitance
change
Char. B : Within 10%
Char. E : Within 15%
D.F. 5.0% max.
I.R.
3 000M min.
Dielectric
strength
Per item 3
*
1
"room condition" Temperature: 15 to 35C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
Cycle Time
1 to 4 30 s max.
5 60 s max.
2005mm
45
Flame
About 8mm
Capacitor
Gas burner
About 10mm thick board
Tissue