SDS

Product Name Alkaline battery - LR23A 12V
Revision date 07-May-2015
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page 3 / 11
Avoid release to the environment
7. HANDLING AND STORAGE
Precautions for safe handling
Handle in accordance with good industrial hygiene and safety practice
Ensure adequate ventilation, especially in confined areas
Avoid creating dust
Avoid contact with eyes
Wash thoroughly after handling
Use personal protection recommended in Section 8
Conditions for safe storage, including any incompatibilities
Keep containers tightly closed in a dry, cool and well-ventilated place
Keep away from heat
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Denmark
European Union
Manganese dioxide (CAS #:
1313-13-9)
TWA: 0.02 mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) Ceiling: 5
mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
TWA: 0.2 mg/m
3
-
Potassium hydroxide (CAS
#: 1310-58-3)
Ceiling: 2 mg/m
3
(vacated) Ceiling: 2
mg/m
3
Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
-
Graphite (CAS #: 7782-42-5)
TWA: 2 mg/m
3
respirable fraction all
forms except graphite
fibers
-
-
TWA: 2.5 mg/m
3
-
Nickel (CAS #: 7440-02-0)
TWA: 1.5 mg/m
3
inhalable fraction
TWA: 1 mg/m
3
(vacated) TWA: 1
mg/m
3
IDLH: 10 mg/m
3
IDLH:
10 mg/m
3
Ni
TWA: 0.015 mg/m
3
TWA: 0.015 mg/m
3
except Nickel carbonyl
Ni
TWA: 0.05 mg/m
3
-
Copper (CAS #: 7440-50-8)
TWA: 0.2 mg/m
3
fume TWA: 1 mg/m
3
Cu dust and mist
-
-
TWA: 1.0 mg/m
3
TWA: 0.1 mg/m
3
-
Lead (CAS #: 7439-92-1)
TWA: 0.05 mg/m
3
TWA: 0.05 mg/m
3
Pb
-
-
TWA: 0.05 mg/m
3
-
Cadmium and compounds
(as Cd) (CAS #: 7440-43-9)
TWA: 0.01 mg/m
3
TWA: 0.002 mg/m
3
respirable fraction
TWA: 0.01 mg/m
3
Cd
TWA: 0.002 mg/m
3
Cd
respirable fraction
TWA: 0.1 mg/m
3
fume applies to any
operations or sectors
for which the Cadmium
standard is stayed or
otherwise not in effect
TWA: 0.2 mg/m
3
dust
applies to any
operations or sectors
for which the Cadmium
standard is stayed or
otherwise not in effect
TWA: 5 ยตg/m
3
(vacated) STEL: 0.3
ppm fume
Ceiling: 0.3 mg/m
3
fume applies to any
operations or sectors
for which the Cadmium
standard is stayed or
otherwise not in effect
Ceiling: 0.6 mg/m
3
dust applies to any
operations or sectors
for which the Cadmium
standard is stayed or
IDLH: 9 mg/m
3
dust
IDLH: 9 mg/m
3
Cd dust
and fume
TWA: 0.005 mg/m
3
-