User Guide

Page 59
8-1 Checking the Condensate Bottle
The condensate bottle collects any water generated within the compressor,
and should be checked WEEKLY, and emptied (if neccessary).
1. Ensure that the machine is switched off.
2. Remove the back door on the monitor cabinet to gain access to the
condensate bottle.
3. Remove the Pozi head screw (M6x25) and remove the bottle complete
with bracket.
4. Unscrew the bottle from the cap and discard the water.
Note: Ensure that any water in the condensate bottle is disposed of
immediately and safely. Do not leave where someone else may see it
and mistake it for drinking water.
8-2 Compressor Assembly
NOTE:
There are no user serviceable parts on the compressor assembly.
Under no circumstances should any regulator valve be adjusted.
Altering the regulator valves could lead to serious damage.