venting requirements
2.8 top exit
!
WARNING
Failure to create a seal to the fi rebox with the exhaust collar assembly will cause the appliance to function
improperly and can cause injury or property damage.
A. Remove the safety barrier and glass door (see "safety barrier & door removal / installation" section).
B. Remove the contents from the fi rebox and set aside.
You will need the exhaust and air inlet collar.
C. To ease assembly, remove the 4 hex head screws,
securing the defl ector from inside the top front of the
rebox (Fig. 1). Set defl ector aside.
D. Remove the 1 1/2" (38.1mm) thick batt of insulation and discard (Fig. 2).
E. Place the 8" (203mm) intake collar and gasket onto the top of the appliance and secure using 4 screws
(Fig. 2).
DEFLECTOR
INTAKE
COLLAR
GASKET
1 1/2” INSULATION BATT
OUTER
COVERPLATE
GASKET
HEAT
SHIELD
Fig. 1
Fig. 2
This appliance has been factory shipped as a top vent appliance.
note:
The manual baggie supplies the gasket and screws (packaged in another separate baggie).
tip:
note: