nishing
10.5 minimum combustible mantel clearances
Combustible Mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clear-
ance needed.
0
34 7
14
16
12 56
12
+
(
,
*
+
7
0
$
1
7
(
/
MANTEL DEPTH
8
10
6
4
18
20
8109
22
24
26
MANTEL DIMENSIONS
Ref Height Depth
A
31 5/8” (80.3cm) N/A
B
8" (20.3cm) 2" (51mm)
C
10" (25.4cm) 4" (102mm)
D
12” (30.5cm) 6" (152mm)
E
14” (35.6cm) 8" (203mm)
ONLY if the Universal Heat Management System is installed, mantel
clearances can be reduced.
0
34 7
12
14
12 56
10
+
(
,
*
+
7
0
$
1
7
(
/
MANTEL DEPTH
6
8
4
2
16
18
8109
20
22
24
MANTEL DIMENSIONS (WITH UHM)
Ref Height Depth*
B
3" (76mm) 2" (51mm)
C
5" (127mm) 4" (102mm)
D
7" (178mm) 6" (153mm)
E
9" (229mm) 8" (203mm)
*Mantel depth must be appropriately sized if placing any valuable items above the fi replace / mantel (see
“clearances around appliance (TV and valuable objects)”).
Risk of fi re! Reduced mantel clearances are ONLY acceptable for applications with UHM installed.
!