Phau Ntawv Qhia

Table Of Contents
EN
W415-2920 / B / 04.26.22
5
standard checklist
1.0 general information
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in fl ame appearance from “HI” to “LO” is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certifi ed for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1 rates and effi ciencies
Fuel Type Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/hr) 30,000
Min. Inlet Gas Supply Pressure 4.5” w.c. (11mb) 11” w.c. (27mb)
Max. Inlet Gas Supply Pressure 7” w.c. (17mb) 13” w.c. (32mb)
Manifold Pressure (Under Flow
Conditions)
3.5” w.c. (9mb) 10” w.c. (25mb)
Installer: please fi ll out appliance
checklist in the owner’s manual
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
important:
Some components and/or media are packaged separately and must be installed in accordance with the
information in this manual.
*Max. inlet pressure not to exceed 13” w.c. (32mb).