EX42 Spec Sheet

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com
72”
(183cm)
min.
ceiling /
enclosure
Recessed
volume must
be added to
the overall size
of the
enclosure.
ELEVATION™ X 42 DIRECT VENT GAS FIREPLACE
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for
the most up to date installation information.
W415-2777 / D / 09.27.21
Wall Penetration
Horizontal vent sections: A minimum
clearance of 3” (76mm) on the top of
the vent to combustibles and 2” (51mm)
on the sides and bottom of the vent to
combustibles is required.
Vertical vent sections: A minimum
clearance of 1” (25mm) all around the
vent pipe on all vertical runs to combus-
tibles is required.
Firestop
assembly
Non-combustible
material
1" [25mm]
0” [0mm] if non-combustible
finishing material is used
such as brick and stone.
Insulated
sleeve
3"
[76mm]
to top
2"
[51mm] to
sides / bottom
Non-combustible
Brick
Combustible
1" [25mm] minimum all sides
for vertical venting sections.
4"
min.
12"
[305mm]
Espaceur
coupe-feu
Matériau
incombustible
1" [25mm]
0” [0mm] si les matériaux
sont inombustible, comme
de la brique et de la pierre.
Manchon
mylar
3"
[76mm]
vers le
haut
2"
[51mm] aux
côtés / au fond
Incombustible
Brique
Combustible
1" [25mm] minimum tous les côtés pour les sections
d'évacuation verticale.
4"
min.
12"
[305mm]
* 72"
(182.8cm)
min.
* 72"
(182,cm)
min.
10 1/4"
10 1/4"
63”
plus rise
Framing
Flush Finish Framing Recessed Finish Framing
72”
(183cm)
min.
ceiling /
enclosure
45 3/4”
48 1/4”
45 3/4”
Max. 5 1/2”*
48 1/4”
* Recess frame can be “backed” with 3/4” ply to support TV mounting hardware.
* The minimum enclosure height is deter-
mined based on volume of air needed in the
enclosure.
22 1/4”
22 1/4”
6”
6”
6”
6”