Instructions / Assembly

W415- 2166 / A / 06.29.16
12
EN
HARDWIRING CONNECTION
If it is necessary to hardwire this appliance, a qualified electrician may remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hardwired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the cur-
rent ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
A. Remove cover plate located beside the power cord to reveal the 7/8” wire hole. Discard cover plate,
screws and insert a box connector into the hole.
B. Remove the lower back panel from the appliance to expose wiring.
C. Remove the power cord strain-relief from the side of the appliance and cut the cord where shown
below. This will be the hardwire connection point.
D. Feed the supply wires through the box connector and the grommet.
E. Using wire connectors connect the common (white) wires together, then the hot (black) wires, and
then the ground (green) wires.
F. Ensure the newly connected wires are kept away from the rotating parts and the circuit board, and
re-install the back panel.
NOTE: This appliance must be serviced from the back, leave enough wire so that the appliance can be
removed from the enclosure without disconnecting the power supply wires.
3.6 HARDWIRE INSTALLATION
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED
SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
Remove 2 screws on cover plate.
2
3
4
1
Hot Wire
Cut
Power Cord
Final Connection
Common Wire
Ground Wire
Box
Connector