Isolated Analog Input Modules User Guide

© National Instruments Corporation 13 SCC-AI Series Isolated Analog Input Modules
Environmental
Operating temperature............................ 0 to 50 °C
Storage temperature ............................... –20 to 70 °C
Humidity ................................................ 10 to 90% RH, noncondensing
Maximum altitude.................................. 2,000 meters
Pollution Degree (indoor use only)........ 2
Safety
The SCC-AIXX meets the requirements of the following standards
for safety and electrical equipment for measurement, control, and
laboratory use:
IEC 61010-1, EN 61010-1
UL 3111-1, UL 61010B-1
CAN/CSA C22.2 No. 1010.1
Note For UL and other safety certifications, refer to the product label, or visit
ni.com/hardref.nsf, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions ............................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity................................................ Evaluated to EN 61326:1997/
A2:2001, Table 1
CE, C-Tick and FCC Part 15 (Class A) Compliant
Note For full EMC compliance, you must operate this device with shielded cabling.
In addition, all covers and filler panels must be installed.
CE Compliance
The SCC-AIXX meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
Note Refer to the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit
ni.com/hardref.nsf, search by model number or product line, and click the
appropriate link in the Certification column.