User Manual

Table Of Contents
8.4.5 Assignments for Knobs
For the Knobs, the Type menu offers the entries Control Change and Program Change. Depend-
ing on the selected entry, a different set of additional parameters is available:
Type Mode RANGE Number Step
Control Change Absolute From 0-126 / To
1-127
0-127
Relative -32 to 31
Relative (Offset) -32 to 31
Program Change From 0-126 / To
1-127
Mode Menu Values for Knobs
For the type Control Change, a Mode menu allows you to select between three operating
modes:
Absolute: In this mode the control element sends absolute values. The From, To, and Reso-
lution parameters are the same as for the other message types (see above).
Relative: In this mode the sent message is in a +1/-1 fashion actually 1/127, which is
then understood by the target software as +1/-1 in that case. This allows the control ele-
ment to set the new Control Change value relatively to its current value. Two parameters
are available:
Step: Defines the increment to use. Increase the Step value to trigger greater jumps in
the target parameter value. If you choose a negative value for Step, the control will be
inverted.
Resolution: Adjusts the sensitivity of the control element to your actions. At high Res-
olution values, a little movement of the control element will be enough to trigger the
message. At lower Resolution values, you will have to move it more frankly to trigger
the message.
MIDI Communication
Using the MIDI Assignment Editor
KOMPLETE KONTROL S-Series - Manual - 102