Material Safety Data Sheet

Product Name Alkaline battery
Revision date 28-Feb-2017
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page 3 / 8
Handle in accordance with good industrial hygiene and safety practice
Ensure adequate ventilation, especially in confined areas
Avoid contact with skin, eyes or clothing
Wash contaminated clothing before reuse
Take precautionary measures against static discharges
Do not breathe dust/fume/gas/mist/vapors/spray
Wash thoroughly after handling
Use personal protection recommended in Section 8
Conditions for safe storage, including any incompatibilities
Keep containers tightly closed in a dry, cool and well-ventilated place
Keep away from heat
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Manganese dioxide
1313-13-9
TWA: 0.02 mg/m
3
Mn
TWA: 0.1 mg/m
3
Mn
(vacated) Ceiling: 5 mg/m
3
Ceiling: 5 mg/m
3
Mn
IDLH: 500 mg/m
3
Mn
TWA: 1 mg/m
3
Mn
STEL: 3 mg/m
3
Mn
Graphite
7782-42-5
TWA: 2 mg/m
3
respirable fraction
all forms except graphite fibers
-
-
brass
12597-71-6
TWA: 1 mg/m
3
Cu dust and mist
-
-
Potassium hydroxide
1310-58-3
Ceiling: 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
Zinc oxide
1314-13-2
STEL: 10 mg/m
3
respirable
fraction
TWA: 2 mg/m
3
respirable fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
(vacated) TWA: 5 mg/m
3
fume
(vacated) TWA: 10 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction
(vacated) STEL: 10 mg/m
3
fume
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
PVC (Chloroethylene, polymer)
9002-86-2
TWA: 1 mg/m
3
respirable fraction
-
-
Appropriate engineering controls
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Respiratory protection
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA
approved respiratory protection should be worn. Positive-pressure supplied air
respirators may be required for high airborne contaminant concentrations.
Respiratory protection must be provided in accordance with current local
regulations.
Hand Protection
Wear protective gloves.
Eye/face protection
Wear safety glasses with side shields (or goggles).
Skin and body protection
Wear suitable protective clothing.
9. PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
Physical state
Soild
Appearance
Colorful Soild
Color
Colorful
Odor
Odorless
Odor Threshold
No information available