User's Manual

CHAPTER 3 NDA-24300
Page 96
Issue 1
SYSTEM MESSAGES
This message displays to indicate the result of a designated connection test (Individual Trunk Access) from a
station.
Test Item (b0-b3 is valid only for
Outgoing trunk test)
1: XXXX XXXX XXXX XXXX 2: XXXX 00XX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➂ ➃ ➄ ➅ ➈ ➉
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON
6-I
STA-Test Connection Data
Default Grade:
3
Grade Modified: Lamp Modified:
11
12
12
12
12 12 12
b0-b2: Kind of Signal
2 = Second Dial Tone
6 = Sender (Delay Dial Start)
7 = Sender (Wink Start)
b3: 0/1 = Data is invalid/valid
b4-b7: Test item
1 = Outgoing Trunk Test
2 = ORT/IRT Test
3 = Sender Test
4 = Digital Conference
5 = Tone Test
6 = Ringing Signal test
0 = Test NG