User's Manual

NDA-24300 CHAPTER 3
Page 97
Issue 1
SYSTEM MESSAGES
-
Station number of testing station
(see table)
Tenant No.
OPTN data
b7 b6 b5 b4 b3 b2 b1 b0
b7 b3 b2 b1 b0
b7 b3 b2 b1 b0
b0-b3: Number of digits of the testing station No.
b4-b7: Error Numbers (see table below)
Error Numbers and Their Meanings
ERROR NO. MEANING
0---
1 The testing station is restricted from activating the service.
2 Route Number Error of the designated trunk
3 Trunk Number Error of the designated trunk
4 Trunk busy
5Sender busy
6 SMDR failure
7 Call origination restriction
8 Register busy
9 Trunk Number Error - when the trunk has been designated
by SHF.
A Trunk busy - when the trunk has been designated by SHF.
B Inter-digit timer expiration
C Register or sender is defective with respect to DP, DP/PB
D Register of sender is faulty with respect to PB
E Tone fault
F Test Processing Error
b4-b7 b0-b3
DC0 DC1
DC2 DC3
DC4 DC5
b0-b3: Tenant No. (1-15)
b7: OP
0/1 = Data in OPTN ( )
is invalid/valid
b0-b3: Tenant No. (Over 15)