User's Manual

NDA-24300 CHAPTER 3
Page 173
Issue 1
SYSTEM MESSAGES
This message displays when a digital line failure is restored to normal.
Accommodated location
Kind of Fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
NON
13-P
Digital Line Restore
Default Grade:
0
Grade Modified: Lamp Modified:
b0-b4: Group No.
b5, b6:Unit No. (0-3)
b7: MG No.
0/1 = Even-numbered MG/Odd-numbered MG
b0-b4: Kind of Fault (HEX)
00 = -
01 = Frame alignment loss PCM down
02 = Bit error rate is over 10
-4
03 = -
04 = Opposite office alarm (AIS) is detected
05 = Dch restores to normal
06 = Multi-frame alignment loss