SYSTEM MESSAGES
This message indicates that an outgoing call (by connection acknowledge system) has not received an ac-
knowledgment signal from the opposite office. As a result, the attempted outgoing call is routed to Reorder
Tone (ROT) connection.
In Case of Station OG/ATT OG/ATT Tandem Connection
Type of connection and station
number digits
-
Calling station number
(See table)
1: XXXX XXXX XX0X XX0X 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
12
11 12
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON
16-F
Sender Start Time Out
Default Grade:
0
Grade Modified: Lamp Modified:
b0-b2: Digits of station number (origination)
b6-b7: 0H=Station OG connection
4H=ATT OG connection
CH=ATT Tandem connection
b4-b7 b0-b3
DC0 DC1
DC2 DC3
DC4 DC5