User's Manual

NDA-24300 CHAPTER 3
Page 199
Issue 1
SYSTEM MESSAGES
This message displays when the IOC card failure, observed in the message [16-T], is detected more than 8
times a day.
IOC circuit card No.
Cause for fault
Reference: See Chapter 4, Section 1.3.3, for the circuit card replacement procedure.
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
SUP
16-U
IOC Failure (Permanent)
Default Grade:
2
Grade Modified: Lamp Modified:
b0: 0/1 = No. 0/No. 1
b0: 0/1 = -/COP Alarm
b1: 0/1 = -/CLK Alarm
b2: 0/1 = -/MEM bus CLK Alarm
b3: 0/1 = -/Abnormal Interruption
b4: 0/1 = -/Infinite Loop Detected