CHAPTER 3 NDA-24300
Page 206
Issue 1
SYSTEM MESSAGES
This message displays when the MB switch on the CCH/DCH card is turned OFF while extracting or inserting
a circuit card or at PM initialization, etc.
Location of CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
NON
17-D
CCH MB Key Turn OFF
Default Grade:
3
Grade Modified: Lamp Modified:
b0-b4: Group No.
b5, b6:Unit No. (0-3)
b7: MG No.
0/1 = Even-numbered MG/Odd-numbered MG