User's Manual

NDA-24300 CHAPTER 6
Page 483
Issue 1
SYSTEM OPERATIONS
Table 6-16 System Initialization by Phase 1 Restart [Procedure #5]
ACTION
7SEG LED/OPE LAMP/KEY
SETTINGS
START
CPU OPE lamp on the DSP of
active CPU light steadily green.
(IMG0-3 lamps flash.)
IMG0 lamp on the DSP of mate
CPU flashes green.
CPU OPE and IMGX lamps on
both DSP go OFF.
STATUS LED (right) on
the CPU is ON.
STATUS LED (right) on
the DSP of CPU is ON.
CPU OPE lamp on the DSP of
active CPU lights steady green.
(IMG0-3 lamps flash.)
IMG0 lamp on the DSP of mate
CPU flashes green.
STATUS LED (right) on
the DSP of active CPU
is ON. (ON LINE)
Press INITIAL START button on the TOPU.
HD Initialization
System Initialization
System starts up again.
Confirm system is operating normally.
Turn ON the EFFECT key on the TOPU. (See Figure 6-58)
Set the SENSE switch on the DSP of CPR to 3.
Set the keys on the TOPU as follows.
PROGRAM KEY NON LOAD
SYSTEM DATA KEY NON LOAD
END
LOAD
NON LOAD
PROGRM
NON LOAD
SYSTEM DATA
LOAD
PZ-DK222