User's Manual

NDA-24300 CHAPTER 8
Page 523
Issue 1
ALMG: Assignment of Alarm Grade Data
ALMG:
Assignment of Alarm Grade Data
1. Functional Outline
This command is used to make a flexible change of system message output grades. Thus, the PBX user can
give a proper alarm grade to each system message according to their requirements. When no data is assigned,
the default alarm grades are automatically adopted.
Note:
This command cannot change the alarm grade for system message 6-A.
2. Parameters
Input data
FK: Fault Message Kind (0-7, 10-17, 20-27, 30-37)
FI: Fault Message Index (A-Z)
LMP: Fault Message Lamp Data (0-3)
0=Lamp OFF
1=SUP Lamp ON
2=MN Lamp ON
3=MJ Lamp ON
GRD: Printout Grade (0-3)
TYPE: Listup Type
1=All Data
2=Changed Data
3=Default Data
SYSM GRD: System Message Output Grade
Note:
0=All Messages
1=Not Used
2=MN/MJ Grade Messages
3=MJ Grade Messages
Note:
When using ALMG command for system message output grade assignment, be sure to set ASYD, SYS
1, Index 91, b2 and b3 = 0, 0. For more information, refer to the Office Data Specifications.