User's Manual

NDA-24300 CHAPTER 8
Page 543
Issue 1
CMWL: Control Message Waiting Lamp
CMWL:
Control Message Waiting Lamp
1. Functional Outline
This command is used to indicate ON/OFF status and to control the Message Waiting Lamp ON/OFF (MW
Lamp) at the station. If the station is a D
term
, this command can also be used to control Message Waiting
Display on the D
term
.
2. Parameters
Input data
TYPE: Type of Input (1,2)
1/2=Designation by Station Number/Designation by LEN
TN:
Note 1
STN: Maximum 5 digits for Business system, and 6 digits for Hotel system.
Note 1
LENS:
Note 2
MCI: Message Center MW Status (0,1)
0/1=OFF/ON
ATT: Attendant Console MW Status (0,1) See the parameter MCI.
STA: Station MW Status (0,1) See the parameter MCI.
VMM: Voice Mail Module MW Status (0,1)See the parameter MCI.
MWLAMP: MW Lamp Status
0/1=OFF/ON
Note 1:
This parameter appears when TYPE= 1.
Note 2: