User's Manual

CHAPTER 3 NDA-24300
Page 44
Issue 1
SYSTEM MESSAGES
This message displays when a fault has occurred to the clock oscillator in the CPU.
Self-CPU Restart Information
Male-CPU Restart Information (FF
H: not mounted)
Related Call Information
Reference: See Chapter 5, Section 6.2, for the repair procedure.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➁➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
b7 b0
Default Alarm:
MN
0-D
CPU Clock Down
Default Grade:
3
Grade Modified: Lamp Modified:
b0: 0/1=-/Monitor Restart
b3: 0/1=-/Initialization
b4: 0/1=Data Copy restart (for Dual-CPU system only)
b5: 0/1=-/MB control
b7: 0/1=ACT/STBY (active system indication after restart)
b0: 0/1=-/Monitor Restart
b3: 0/1=-/Initialization
b4: 0/1=-/Data Copy restart (for Dual-CPU system only)
b5: 0/1=-/MB control
b7: 0/1=ACT/STBY (active system indication after restart)
b7: 0/1=Released/Not released