User's Manual

CHAPTER 3 NDA-24300
Page 66
Issue 1
SYSTEM MESSAGES
This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more
than 16 times an hour. At this time, the faulty DLKC card is down and its switching network automatically
changes over.
System status of faulty DLKC card
Error Code
Details on Switching Network
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b1 b0
Default Alarm:
MN
1-U
DLKC Data Transfer Failure (Permanent)
Default Grade:
3
Grade Modified: Lamp Modified:
b0: 0/1 = No. 0 system / No. 1 system
01H: Firmware fault
02H: Data transfer time out to DLKC
03H: No answer time out (at DLKC)
04H: Data parity error
b0: Status of Speech Path System (including DLKC)
0/1 = No. 0 system is ACT/No. 1 system is ACT
b1: Status of basic clock
0/1 = No. 0 system is ACT/No. 1 system is ACT