User's Manual

NDA-24300 CHAPTER 3
Page 69
Issue 1
SYSTEM MESSAGES
This message displays when a C-level program abnormal state is detected as permanent. When the Port Mi-
croprocessor (PM) on an LC/TRK card detects the abnormal state, the PM places the card into make-busy sta-
tus. If the failure occurs more than 15 times an hour, the system judges the failure as permanent and issues the
this system message.
Faulty Circuit Card Mounting
Location
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
MN
3-B
C-Level Infinite Loop (Permanent)
Default Grade:
3
Grade Modified: Lamp Modified:
b0-b4: Group
b5-b6: Unit (0-3)
b7: Module Group (0/1)