User's Manual

CHAPTER 3 NDA-24300
Page 72
Issue 1
SYSTEM MESSAGES
At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as tem-
porary.
Faulty Circuit Card Location
PM Restart Type
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b0
Default Alarm:
SUP
3-E
Lock-Up Failure (Temporary)
Default Grade:
1
Grade Modified: Lamp Modified:
b0-b4: Group
b5-b6: Unit (0-3)
b7: Module Group
0/1 = Even-numbered MG/Odd-numbered MG
b0: 0/1 = B-monitor/Initial Restart